BATTERY KNOWLEDGE

1. What is a valve-regulated lead-acid battery?

As opposed to traditional flooded batteries, valve-regulated maintenance-free lead-acid batteries do not require maintenance. VRLA’s are sealed to prevent any acid leakage or dissipation. In addition, one-way safety valves automatically release excess gases if pressure exceeds safety limits. This allows the battery to maintain healthy pressure levels without outside support.

2. What kinds of valve regulate maintenance free lead-acid battery?

According to the technology, there are two kinds of lead-acid batteries: general type (AGM) and GEL. AGM battery uses glass fiber cotton (Absorbed Glass MAT) as a separator, and liquid electrolyte (the electrolyte is absorbed on plate and separator, and cannot flow in the battery). The GEL battery has silica as a solidifier and the electrolyte is adsorbed on the plate as colloid. Accordingly, to using purpose, they also can be mainly divided by usage: starting batteries, stationary battery, and traction type, etc.

3. What is the rated capacity of the battery?

In the conditions of the stipulated design (such as temperature, discharge rate, and final voltage, etc.), the rated capacity means the battery should be able to release the lowest capacity, the unit is ampere-hour, expressed as a symbol of C. Capacity is strongly influenced by the discharge rate, so we often show the discharge rate by Arabic numerals at the lower right corner of the letter “C”, such as C20=50Ah, it means that under the condition of 20-hour rate to discharge to the final voltage, the capacity is 50 ampere hours. Informally, the rated capacity of 50 ampere hour of battery in full charge of state, the battery can be discharged for 50 hours with 1 A of current.

4. What is the battery open-circuit voltage (OCV)?

Open-circuit voltage (OCV) refers to a battery that is disconnected from any circuits and has no external currents flowing between terminals. An electric meter measures the voltage between the two terminals; and though the OCV cannot be utilized as a standard to measure battery voltage, the differences in electrical potential can be compared to one another to determine the state of the charged battery.

5. What is end-of discharge (EOD) or cut-off voltage of the battery?

End of discharge voltage is the allowable minimum voltage of battery discharging. When the battery voltage is lower than the EOD, the voltage of the battery will drop rapidly if discharged continuously, and it will over-discharge the battery. This may result in permanent damage to the battery. The EOD is connected with discharge rate, and discharge current affects the EOD voltage directly. Under the stated end of discharge voltage, the greater the discharge current, the smaller capacity of the battery.

6. What is the depth of discharge (DOD)?

During battery use, the battery capacity will discharge a percentage of it rated capacity. This is called depth of discharge (DOD); DOD at 60% means the discharged capacity of the battery has reached 60%, and 40% of its capacity remains.

7. What is the floating use and cycling use of batteries?

Cycling use: The battery is used as a direct power supply for equipment, which mainly applies to the circulation charge and discharge of electrical equipment. Float use: The battery is used as an emergency power supply for equipment to provide emergency power or energy storage in the event of a power outage (ex: power plant, UPS power supply, emergency lighting, etc.).

8. What are the methods of battery charging?

The main methods of battery charging are constant-current charging, constant-voltage charging, constant-current with limited voltage charging, equalizing charging, float charging, and pulse charging.

9. What are the requirements for battery storage? 

Proper storage requires an environment with stable flooring, good ventilation, dry conditions, and lower temperatures (around 15- 25 degrees Celsius). Even when in storage, the battery should be charged every 3-6 months.

10. How to do routine Maintenance for lead acid battery?

Battery owners often mistakenly believe that VRLA’s are maintenance-free, when in fact, battery upkeep and maintenance are necessary to ensure optimal function. It is recommended to regularly keep operating records and to check batteries monthly for the following:
①The floating voltage of batteries and battery groups,
②The temperatures of the shell and pole of the battery,
③The battery shell shows no signs of deformation or leakage,
④Any seepage or acid fog collecting near poles or valves,
⑤If the connection strip is tightened there will be a loose connection with the battery, which increases the resistance of the joint during large current charging and discharging. This can lead to overheating of the connector or even melting of the battery core. If not resolved, this may start a fire.

ABOUT LICHEN POWER

1. Are you a factory? 

Yes, we have plate factory and battery assembly workshop, the factory address is located in 10,Shaji Road, Shanggao County,Yichun city, Jiangxi Province.China.

2. Can you print my logo on the battery & Master Carton

Yes, OEM is available; we can print your logo on the battery case freely. Welcome to send us your logo design and discuss with us about the details.

3. How long is your delivery time?

Usually it takes about 20-30 days for production varies with products. 15 days can be done if urgent situation.

4. What’s your payment term?

We accept T/T, Western Union, L/C and so on. 

5. What is your battery capacity range?

2V 100ah-3000Ah; 12V 0.8Ah-300Ah; 6V 1.2Ah-200Ah;4V 0.1Ah-10Ah

6. What kinds of battery do you have?

We have AGM Battery, GEL Battery, UPS Battery, Solar Battery, Motorcycle battery etc.

7. What is your backup battery life cycle? 

Life cycle is connecting with discharge depth of discharge (DOD).  If 30% DOD, more than 1400 cycle times.  If 50% DOD, more than 800 cycle times. If 100% DOD, more than 300 cycle times.

8. What is your warranty policy?

12V 0.8Ah-28Ah, 6V1.2Ah-14ah, 4V4Ah-9Ah;1 year warranty;12V 33Ah-250Ah, 6V100Ah-200Ah, 2V100Ah-3000Ah;2 years warranty.

9. Do you offer free samples for testing?

Yes, surely we can, normally the clients only need to pay the freight.

10. What is your MOQ requirement? 

Normally we don’t have MOQ limit, only if few Qty, the battery price would be higher than large QTY.

 

VRLA BATTERY TERMINAL TYPE

VRLA BATTERY TERMINAL TYPE | Lichen Power

Why Choose Lichen Power?

We have own lead plate factory

We have own plate factory & SLA battery assembling factory, more than 10 years experience.

Qualified materials

We use highest purity (99.997%) of lead to produce lead acid battery

Strict QC System

100% full inspection of all finished batteries, ensure battery quality and performance.

Competitive Price

Advanced automation equipment and scientific ISO system management effectively reduce battery costs and improve market competitiveness.

Professional Service

Provide professional pre-sales, in-sales and after-sales services to improve customer satisfaction with product quality, delivery time, warranty, etc.